Continuous Positive Airway Pressure (CPAP) is delivered to correct hypoxia. Indications include cardiogenic pulmonary oedema and atelectasis.
CPAP recruits collapsed alveoli and improves gas exchange by:
High flow oxygen therapy delivered through AquaNASE® nasal cannula provides heated and humidified gases at flows up to 80 L/min.
Positive End Expiratory Pressure (PEEP) is used to maintain pressure on the lower airways at the end of the breathing cycle which prevents the alveoli from collapsing during expiration. Clariti PEEP valves are fixed value colour coded valves made from a transparent material which allows monitoring of the patient’s respiratory rate and blockage assessment while a highly fluorescent valve facilitates observation of valve functionality.
A range of CPAP components are available for use with our CPAP face masks, headgear and breathing systems. Components can be assembled to your requirements or purchased separately.
The AquaVENT® Transition System comprises of a HFOT breathing circuit and a CPAP Transition Kit that allows for up to 7-day single patient use. Its ability to transition between therapies prioritises patient well-being and helps you streamline delivery of care.
Resources
Video Material
Print Material
Product Codes
AMCPUK01258
CPAP adapter limb (FD140)
20
AMCP1409-032
CPAP adapter limb (POINT system)
20
AMVC1792-004
Ventilator circuit, adult, single limb, heated for use with 850 series heater humidifier, length 1.5m in smooth bore tubing with C02 exhalation valve (KOEV valve) with tubing and 0.2µm hydrophobic gas filter with humidification limb length 0.8m in corrugated tubing with auto-fill humidification chamber with bacterial viral breathing filter.
20
AMVC1792-113
Ventilator circuit, adult, single limb, heated for use with 850 heater humidifier, length 1.6m in standard corrugated tubing with manometer tubing and 0.2µm hydrophobic gas filter with vented Bi-Level face mask SMALL and headgear with humidification limb length 0.8m in standard corrugated tubing with auto-fill humidification chamber with bacterial viral breathing filter with CO2 exhalation valve (KOEV valve) bagged separately.
10
AMCP1409-003
AquaVENT® CPAP limb, adult, heated for use with ‘850’ series heater humidifiers, length 1.6m and auto-fill humidification chamber with humidification limb length 0.6m in standard corrugation tubing.
20
AMHO1509-008
AquaVENT® Humidified Oxygen System, adult, heated for use with ‘850’ series heater humidifiers length 1.5m with humidification limb, auto-fill humidification chamber with AquaNASE® Nasal High Flow System, size MEDIUM (5mm).
20
AMCPUK01243
AquaVENT® CPAP System, adult, single limb heated for use with ‘850’ series heater humidifiers, length 1.5m with heated inspiratory limb with 0.45m humidification limb with manometer line assembly with auto-fill humidification chamber with safety valve.
10
AMCPUK01241
AquaVENT® CPAP System, adult, single limb heated for use with ‘850’ series heater humidifiers, length 1.5m with heated inspiratory limb with 0.9m humidification limb with manometer line assembly with 5cm patient PEEP valve with auto-fill humidification chamber with safety valve.
10
AMVC1792-004
Ventilator circuit, adult, single limb, heated for use with 850 series heater humidifier, length 1.5m in smooth bore tubing with C02 exhalation valve (KOEV valve) with tubing and 0.2µm hydrophobic gas filter with humidification limb length 0.8m in corrugated tubing with auto-fill humidification chamber with bacterial viral breathing filter.
20
AMVC1792-013
Ventilator circuit, single limb, adult, non-heated, length 1.8m in smooth bore PE tubing with CO2 exhalation port and bacterial viral breathing filter.
20
AMCA1402-6
Adult, 1.8m length single limb circuit in smooth bore PU tubing 22mmØ.
25
AMVC1792-092
Ventilator circuit, single limb, adult, non-heated, length 1.8m in smooth bore PE tubing with bacterial viral breathing filter.
20
AMVC1792-016
Ventilator circuit, adult, single limb, non-heated, length 1.8m in smooth bore tubing with exhalation valve with double swivel plain patient elbow with bacterial viral breathing filter with supplemental oxygen tubing.
20
PEEP valve 7.5cm H2O.
10
PEEP valve 10.0cmH2O.
10
AMPV9012
PEEP valve 12.5cmH2O.
10
AMPV9015
PEEP valve 15cmH2O.
10
AMPV9020
Safety valve 20.0cmH2O.
10
AMPV9003
Safety valve 2.5cmH2O.
10
AMPV9005
Safety valve 5cmH2O.
10
Adjustable PEEP valve 5.0 – 20.0cmH2O.
10
Related Products
We are committed to protecting and preserving the privacy of our visitors when visiting our site or communicating electronically with us.
THERAPIES
Armstrong Medical Ltd is a limited company registered in Northern Ireland
Wattstown Business Park, Newbridge Road, Coleraine, Co. Derry/Londonderry, BT52 1BS, United Kingdom
VAT Number: GB432578934
Company Number: NI025560